NLFit-Dialog-Button
The buttons in the middle portion of the NLFit dialog box provide controls over the fitting process and access to the Fitting Function Organizer. The Organizer is used to edit or define new fitting functions.
Click to search an appropriate function and insert it into dialog with Search Fitting Function dialog.
If you have selected a built-in function, this button opens the Fitting Function Organizer. If you have selected a user-defined function, this button opens the Fitting Function Builder.
Save changes to the current user-defined function.
See: Fitting Function Organizer.
Restore default order of peaks. Available only after using Sort Peaks, and when Number of Replicas is more than 0.
Open Sort Peaks dialog. Peaks can be sorted by Centers, Widths, or Amplitudes, in Ascending or Descending order. Available when Number of Replicas is more than 1.
Initialize the parameters with the parameter initialization code (or supplied values). See:Parameter Initialization.
Perform a Simplex approximation for parameter initialization.
See: Downhil Simplex Algorithm
Calculate the current reduced Chi-square value. The result will be displayed in the Message tab of the dialog's lower panel. See: Theory of Nonlinear Curve Fitting.
Perform a single Levenberg-Marquardt (LM) iteration. The result will be shown in the Message tab of the lower panel. See: Theory of Nonlinear Curve Fitting.
Perform the fit. Levenberg-Marquardt (LM) iteration will be carried out until the tolerance is reached, or the number of iterations has reached the maximum specified in Fit Control branch in the Advanced page of the Settings tab. See: Theory of Nonlinear Curve Fitting.
Perform the fit and output the results worksheets. See also: Fit Parameter Values Displayed in Change Parameter Mode.
Accept the current parameter values, close the NLFit dialog, and generate reports. See also: Fit Parameter Values Displayed in Change Parameter Mode.
Once clicked, the Fit until converged button becomes an OK button. Click OK to close the dialog. See also: Fit Parameter Values Displayed in Change Parameter Mode.
Cancel the fit and close the dialog.
Toggle the top and bottom panels on and off.
When you perform curve fitting with recalculate mode set to Manual or Auto, you can easily reopen the NLFit dialog from an output worksheet or graph. Simply left-click the lock icon on the worksheet or graph, and then click Change Parameters.
The parameter values displayed in the Parameters tab are the same as when the dialog was last closed. As there is more than one way to close the dialog in a fitting session, the displayed values will depend on the actions performed by the user: